Empowering a Sustainable Future, One Solar Product at a Time.

In Stock

Affordable Wholesale 600-3000W MPPT Hybrid Wind Solar Controller Charge And Discharge Regulator Deluxe Version For 12v 24v 48v Colorful LCD Display

SKU: 1005004698401577
Safe Payment Guarantee:


Products related to power generation systems



Product Video

























Product Introduction


Colorful display with 4-key man-machine interfaceis more comprehensive, clearer, andconvenient;

Wind charging ensures MPPT charging at low wind speed.And three-stage charging mode:MPPT charging; lifting charging; floating charging.

Solar three-stage charging mode:CC (constant current); lifting charging; floating charging.

Optional APP to inspect the controller operating parameters

The controller has comprehensive protection functions such as overcharge, over discharge and overloadetc.;

Four battery types charging mode can be selected for operation: Lead-acid battery, Ternary lithium battery, Lithium iron phosphate, Custom ;


Product Highlights

The controller adopts color screen design, the display information is more comprehensive, the display interface is clearer, the controller supports WIFI module and GPRS module to expand and implement APP cloud monitoring(optional).


Application

The controller is suitable for solar off-grid system, automatically controls charging and discharging, and can be applied in communication base stations, household systems, street lighting systems, monitoring and other fields.


Indicator Function

The LED indicators on this controller showing

1) Red indicator:    in charging

2) Green indicator: output power from battery

The function definition is shown in the table below.


Protection Function

PV module polarity reverse connection

When the polarity of the PV module is reversed, the controller will not charge. The PV over and under voltage alarms can be viewed through APP. The controller will not be damaged. After re-wired correctly, the PV charging will resume normal operation.

PV under-voltage

When the PV array charging voltage is below the controller input voltage range, the controller stops charging the battery pack.

PV over-voltage

When the charging voltage of the PV array exceeds the input voltage range of the controller, the controller stops charging the battery pack, and the PV over-voltage alarm fault can be detected by the APP.

Solar charging over-current

When the PV array charging current exceeds the internal set value, the display will report IPV and ERROR flashing and stop charging;

Wind under-voltage

When the Wind charging voltage is lower than the controller input voltage range, the controller stops charging the battery pack.

Wind over-voltage

When the Wind charging voltage exceeds the unloading voltage value of the Wind, the controller turns on the unloading function, and the display shows that the unloading resistance icon lights up.

Battery polarity reverse

When the polarity of the battery is reversed, the controller fuse or other device may be damaged. It is strictly forbidden to terminate the battery.

Battery under-voltage

When the battery voltage is lower than the set under-voltage value, the display shows U under and ERROR flashing alarms, and the load output is automatically stopped to prevent the battery from being over-discharged and damaged.

Battery over-voltage

When the battery voltage reaches the over-voltage protection setting value, the display shows U over and ERROR flashing alarms, and automatically stops charging the battery to prevent the battery from being overcharged and damaged.

Night anti-reverse

At night, since the battery voltage is greater than the voltage of the solar, the automatic protection prevents the battery voltage from being discharged through solar;





(1) The display adopts color screen design, the display information is more comprehensive, the display interface is clearer, and the 4-key man-machine interface and operation setting are more convenient;

(2) The MPPT control algorithm used for Wind charging ensures MPPT charging at low wind speed.

(3) Wind three-stage charging mode:MPPT charging; lifting charging; floating charging.

(4) Solar three-stage charging mode:CC (constant current); lifting charging; floating charging.

(5) 12V/24V battery system automatically recognizes, or 24V/48V battery system automatically recognizes (Optional).

(6) RS485 communication can provide communication protocol to facilitate unified management and secondary development for customer.

(7) The controller operating parameters can be viewed and set through the mobile phone APP( Optional ).

(8) The controller has comprehensive protection functions such as overcharge, over discharge and overload;

(9) Four battery types charging mode can be selected for operation: Lead-acid battery, Ternary lithium battery, Lithium iron phosphate, Custom ;

(10) The controller has various load control modes, the load has two outputs, and the output power and time can be set;

(11) The controller has wide adaptability, adaptive day and night.



1. System Parameter


Model

600W30

1000W50

1200W60

1600W80

2000W100

2400W120

3000W150

4000W200

System Rated Voltage

12V(9V-16VDC)

24V(18V-32VDC)

48V(42V-60VDC)

Solar Module

Voc

27.6V

55.2V

105V

Vmp

>Vbat+1V

>Vbat+1V

60~90V

Imp

25A

40A

25A

33A

20A

25A

33A

41.7A

Workable Power

0W~300W

0W~500W

0W~600W

0W~800W

0W~1000W

0W~1200W

0W~1500W

0W~2000W

Wind Turbine

Rated Voltage

12VAC20.8VDC

24VAC(41.6VDC

48VAC83.1VDC)

Rated Current

25A

40A

25A

33A

20A

25A

33A

41.7A

Workable Power

0W~300W

0W~500W

0W~600W

0W~800W

0W~1000W

0W~1200W

0W~1500W

0W~2000W

Battery

Max Charging

30A

30A

33A

Special Note:The following are the optimal parameter settings, please do not modify

Uunder

Over Discharge Voltage

10.8V

21.6V

43.2V

Runder

Over Discharge Return

13.1V

26.2V

52.4V

Uover

Over Charge Voltage

15.5V

31.0V

62.0V

Rover

Over Charge Return

15.0V

30.0V

60.0V

BCV

Increase Charge

14.4V

28.8V

57.6V

Float

Floating Charge

13.8V

27.6V

55.2V

Ufanbraking

Wind Breaking Voltage

25.6V

51.2V

102.4V

DC Load

Out Power

0W~180W
(Per one-way)

0W~700W
(Per one-way)

0W~1400W
(Per one-way)

Rated Voltage

12VDC

24VDC

48VDC

Current Max

30A(15A*2)

60A(30A*2)

60A(30A*2)

Conversion Efficiency

﹥98%

Operation Mode

Default to streetlight mode

Environment

Temperature

1) Working:-20℃~50; 2)Storage:-30℃~70

Humidity (°C)

10% ~ 90% No condensation

Protection Grade

IP30



2. Battery Parameter

Model

600W30
1000W50

1200W60
1600W80

2000W100
2400W120
3000W150
4000W200

System Voltage

12V
(9V-16VDC)

12V
(9V-16VDC)

24V
(18V-32VDC)

48V
(42V-60VDC)

Special Note: The following are the optimal parameter settings, please do not modify

Lead acid battery

Overvoltage

1317V

15.5V

2634V

5268V

Overcharge Return

1317V

15V

2634V

5268V

Increase Charge

915V

14.4V

1830V

3660V

Floating Charge

915V

13.8V

1830V

3660V

Undervoltage

713V

10.8V

1426V

2852V

Undervoltage return

915V

13.1V

1830V

3660V

Lithium Iron Phosphate LiFePO4

Default Voltage

11.1V
(3*3.7V)

11.1V
(3*3.7V)

22.2V
(6*3.7V)

44.4V
(12*3.7V)

Overvoltage

10.515V

13.5V

2130V

4260V

Overcharge Return

10.515V

12.6V

2130V

4260V

Increase charging

10.515V

12.4V

2130V

4260V

Floating charge

613.5V

12.0V

1227V

2454V

Undervoltage

613.5V

9.3V

1227V

2454V

Undervoltage return

613.5V

10.5V

1227V

2454V

Adjustable Battery QTY

34 PCS

3 PCS

68 PCS

1418 PCS

Ternary lithium battery

Default Voltage

9.6V
(3*3.2V)

9.6V
(3*3.2V)

19.2V
(6*3.2V)

38.4V
(12*3.2V)

Overvoltage

912V

11.7V

1824V

3648V

Overcharge Return

912V

11.1V

1824V

3648V

Increase charging

912V

10.8V

1824V

3648V

Floating charge

912V

10.2V

1824V

3648V

Undervoltage

612V

8.4V

1224V

2448V

Undervoltage return

612V

9.6V

1224V

2448V

Adjustable Battery QTY

34 PCS

3 PCS

68 PCS

1418 PCS


































Get Quote
Fill out my online form.

You have no items in your cart