Fill out my online form.
Special offer!! 400W 12/24V AC Wind Turbine Generator with 1200w hybrid MPPT wind solar controller for Hybrid Home Power System
To meet most of customers' requirements, we promote an economy wind turbine generator which is cheap and good quality.
Considering the generator can start easily, our engineers develop the lower start-up wind speed. Start the wind turbine generator only needs 2m/s wind speed. 20-year long life-span wind power generator is a good choice.
And with a high cost efficiency reliable MPPT Hybrid Wind Solar Controller, you can easily build your own HYBRID WIND SOLAR POWER SYSTEM (only need to add 12/24v battery bank and grid tie/off grid inverter, we can supply together if you need).
Instruction
1. Starting up with low speed; high wind energy utilization; beautiful appearance; low vibration
2. Human friendly design, easy installation, maintenance and repair.
3. Precise injection molding blades together with the optimized design of aerodynamic contour and structure, the blades have such advantages: high utilization of wind energy which contributes to the annual energy output.
4. the generators, adopting patented permanent magnet rotor alternator, with a special kind of stator design, efficiently decrease resistance torque.Meanwhile, it makes the wind turbines match the generators quite well and increase its reliability.
Note: 400W wind turbine only have white color blades for choice. If you need other colors, the MOQ should be more than 100pcs.
Product Features
Easy installation
Delicate Structure
1. Body frame; 2. Flange base; 3. Steel bracket (tower); 4. Axis; 5. Hub; 6. Blades; 7. Anti-slack nut; 8. Fairing; 9. Bolt; 10. Flat washer; 11. Elastic washer; 12. Nut; 13. Stainless screw; 14. Anti-slack.
ParametersModel | FT1.2S-100 | FT1.2S-200 | FT1.3S-300 | FT1.4S-400 |
Rated power | 100W | 200W | 300W | 400W |
Maximum power | 130W | 220W | 310W | 410W |
Rated voltage | 12/24V | 12/24V | 12/24V | 12/24V |
Start-up wind speed | 2.0m/s | 2.0m/s | 2.0m/s | 2.0m/s |
Rated wind speed | 10m/s | 11.5m/s | 13m/s | 13m/s |
Survival wind speed | 55m/s | 55m/s | 50m/s | 50m/s |
Top net weight | 6.0kg | 6.2kg | 6.5kg | 6.8kg |
Wheel diameter | 1.2m | 1.3m | 1.35m | 1.4m |
Number of blades | 3 or 5 | |||
Blades material | Nano nylon glass fiber | |||
Generator | 3 phase permanent magnet synchronous AC generator | |||
Magnet | NdFeB | |||
Generator case | Die-casting aluminum | |||
Control system | Electromagnet | |||
Speed regulation | Automatically adjust windward direction | |||
Working temperature | - 40°C - + 80°C | |||
Design life | 20 Years | |||
Gross weight (3 blades) | 8.5kg | 8.8kg | 9kg | 9.5kg |
Gross weight (5 blades) | 9kg | 9.3kg | 9.5kg | 10kg |
Package dimension | 70X30X20CM | 70X30X20CM | 70X30X20CM | 70X30X20CM |
Part.2 MPPT HYBRID WIND SOLAR CONTROLLER (600W Wind + 600w Solar, 12V&24V auto.)
Features:
1.The Wind turbine charging part and Solar charging part are independent of each other, can make Wind turbine controller or solar controller using independent (As a Wind turbine controller cannot use light control function).
- Wind turbine charging adopted booster MPPT technology, which makes under low wind speed, the Wind turbine's electricity can still be used;
- In the high wind speed or the Wind turbine of power is beyond the scope of the battery and load absorption, the controller immediately launched the stepless unloading function,protection system of the equipment.
- Solar charging using in series MOS tube PWM technology, which makes the controller power consumption is small, the system more stable
2.Discharge part working mode can be set, light control mode, time control function etc, The user can be set up according to the requirements on its own combination.
3.Manmachine interface of the controller USES a custom LCD screen and four key operation mode, the user to use simple and easy to use, popular and easy to understand, convenient and quick.
4. The controllers with perfect protection function, including: lightning counter-attack, solar charger, over-voltage automatic braking, storage battery reverse connect and open protection, etc.
Parameters
Model | 500W30 | 450W30 | 750W50 | 900W60 | 1100W60 | 1200W60 | 1400W80 | |
Rated voltage | 12V/24V Automatic identification system voltage | |||||||
PV input power | 200W | 150W | 250W | 300W | 500W | 600W | 600W | |
Wind turbine power | 300W | 300W | 500W | 600W | 600W | 600W | 800W | |
charging | charging | 20.8A/41.7A | 18.75A/37.5A | 15.6A/31.25A | 37.5A/75A | 45.8A/91.6A | 50A/100A | 58.3A/116.6A |
Even charge protection | 14.4V±1%(12V) | 28.8V±1%(24V) | ||||||
floating Charge | 13.8V±1%(12V) | 27.6V±1%(24V) | ||||||
Even charge recover | 13.2V±1%(12V) | 26.4V±1%(24V) | ||||||
Temperature Compensation | -24mV/ Degree | -48mV/ Degree | ||||||
Over Discharge | Shut off (DC) | 10.8V±1%(12V) | 21.8V±1%(24V) | |||||
Resume (DC) | 12.3V±1%(12V) | 24.6V±1%(24V) | ||||||
Over Voltage | Shut off (DC) | 16V±1%(12V) | 32V±1%(24V) | |||||
Resume (DC) | 15V±1%(12V) | 30V±1%(24V) | ||||||
No-load Current | ≤0.1A | |||||||
Voltage drop (DC) | ≤0.5V | |||||||
Control mode | Wind turbine MPPT charge function, PWM uninstall function, PWM over-current limiting | |||||||
Boost charge | Flexible independent step-up circuit (optional) | |||||||
Display | LCD | |||||||
Show parameters | voltage,charge current,battery volumetric | |||||||
Protected type | Lightning protection, solar cells, anti-anti-charge protection, battery open-circuit protection, battery reversal protection, over speed and over-voltage soft automatic brake protection, overload protection. | |||||||
Heat emanation way | radiator | |||||||
Working Temperature | -25 ~+55 | |||||||
Height | ≤5500m(2000m above the need to reduce power use) | |||||||
Environment humidity | 0~90%,No condensation | |||||||
Warranty | one year | |||||||
Weight | 1. Net Weight: 1.20KG 2. Gross Weight: 2.7 KGS/PC(controller+dump load) | |||||||
Size(L*W*H) | 1. 162×140×64(MM) 2. Packing Size: 26X22X20CM |
SYSTEM CONNECTION
1, Grid Tie Wind Solar Hybrid Power System Connection
2,Off Grid Wind Solar Hybrid Power System Connection
Off grid inverter transfer battery power to appliances directly. It is independent from grid. It means when grid fails, the system still can work.
And please kindly note below two tips:
1.Total power of all your loads should be lower than inverter power.